Shell Diala S4 ZX-I

(1 customer review)

Short Description

Shell Diala S4 ZX-I is your reliable choice for transformer insulation. Its zero sulfur content, exceptional performance, and global availability make it the preferred option for critical applications. Ensure longevity and efficiency with Shell Diala S4 ZX-I.

Specifications:

  1. Density @ 20°C: 805 kg/m³
  2. Flash Point: 135°C
  3. Pour Point: -42°C
  4. Neutralization Value: 0.01 mg KOH/g
  5. Total Sulfur Content: Below 1 ppm detection limit of ASTM D5185
Report Abuse
Description

Description

Shell Diala S4 ZX-I is the new electrical insulating oil from Shell, meticulously designed to meet the challenges posed by the latest generation of power transformers. This premium oil offers an extended lifespan, ensuring optimal performance and peace of mind. Let’s delve into the details of this remarkable product.

 

Performance of Shell Diala S4 ZX-I

  • Extended Oil Life: Shell Diala S4 ZX-I is a fully inhibited oil that delivers outstanding oxidation performance, resulting in a longer oil life. This longevity translates to reduced maintenance costs and enhanced reliability for your transformers.
  • Suitable for High Load Applications: Whether you’re dealing with heavy-duty transformers or demanding conditions, Shell Diala S4 ZX-I performs exceptionally well, ensuring uninterrupted power supply.

 

Features of Shell Diala S4 ZX-I

  1. Zero Sulfur Content: Manufactured from zero sulfur base oils using Shell’s cutting-edge GTL (gas-to-liquid) technology, this insulating oil provides peace of mind with its intrinsic non-corrosive properties toward copper. No need for passivation or other additives.
  2. Global Availability: The base oils used in Shell Diala S4 ZX-I offer high compositional consistency and excellent antioxidant response. Plus, they are globally available and free from PCBs, DBDS, and passivators.
  3. Copper Corrosion Resistance: Shell Diala S4 ZX-I meets both established and new industry copper corrosion tests, including DIN 51353, ASTM D1275, IEC 62535, and ASTM D1275B.

 

Benefits of Shell Diala S4 ZX-I

  1. Transformer Protection: With its zero sulfur content, this oil ensures non-corrosiveness toward copper, safeguarding your valuable transformers.
  2. System Efficiency: The excellent low-temperature viscometric properties of Shell Diala S4 ZX-I facilitate proper heat transfer even at very low starting temperatures.
  3. Health and Safety: Shell Diala S4 ZX-I is unlikely to present significant health or safety hazards when used correctly. It is free from polychlorinated biphenyls (PCB).

 

Specifications

  • Density @ 20°C: 805 kg/m³
  • Kinematic Viscosity @ 40°C: 9.6 mm²/s
  • Flash Point: 135°C
  • Pour Point: -42°C
  • Neutralization Value: 0.01 mg KOH/g
  • Total Sulfur Content: Below 1 ppm detection limit of ASTM D5185

 

Certifications

  • IEC 60296 (Edition 5, 2020): Type A, fully inhibited high-grade oil
  • IEC 60296 Ed4 (2012): Table 2 Transformer Oil (I) (Inhibited oil) Section 7.1 (“Higher oxidation stability & low sulfur content”)

 

Health and Safety

  • Shell Diala S4 ZX-I is unlikely to present any significant health or safety hazard when properly used.
  • Avoid skin contact and use impervious gloves when handling used oil.

 

Color

  • Clear, free from sediment and suspended matter

 

Applications

  • Suitable for power transformers, instrument transformers, and bushings
  • Ideal for cooling servers by immersion

 

Industries Where Shell Diala S4 ZX-I Is Popular

  • Power utilities
  • Industrial plants
  • Electrical equipment manufacturers
  • Renewable energy installations

 

Price of Shell Diala S4 ZX-I

For pricing information and to place an order, contact us today. Our team will provide you with the best price for this high-quality insulating oil.

 

Flash Point of Shell Diala S4 ZX-I

  • The flash point of Shell Diala S4 ZX-I is 135°C.

 

Drop Point of Shell Diala S4 ZX-I

  • Shell Diala S4 ZX-I does not have a drop point, as it is not a solid material.

Viscosity of Shell Diala S4 ZX-I

  • Kinematic viscosity at 40°C9.6 mm²/s

Frequently Asked Questions (FAQs) about Shell Diala S4 ZX-I

  1. Is Shell Diala S4 ZX-I suitable for both new and existing transformers?
    • Yes, Shell Diala S4 ZX-I is designed for both new installations and as a replacement oil for existing transformers.
  2. Can I mix Shell Diala S4 ZX-I with other insulating oils?
    • It is recommended to avoid mixing different insulating oils. Consult with our experts before making any changes.
  3. What certifications does Shell Diala S4 ZX-I hold?
    • Shell Diala S4 ZX-I complies with IEC 60296 (Edition 5, 2020) and IEC 60296 Ed4 (2012) standards.

 

Shell Diala S4 ZX-I Datasheet

Property Value
Density @ 20°C 805 kg/m³
Flash Point 135°C
Pour Point -42°C
Neutralization Value 0.01 mg KOH/g
Total Sulfur Content Below 1 ppm detection limit of ASTM D5185

Shell Diala S4 ZX-I is a premium insulating oil designed for modern transformers. Its exceptional performance and global availability make it the preferred choice for critical applications. Ensure longevity and efficiency with Shell Diala S4 ZX-I.

Specifications:

  • Density @ 20°C: 805 kg/m³
  • Flash Point: 135°C
  • Pour Point: -42°C
  • Neutralization Value: 0.01 mg KOH/g
  • Total Sulfur Content: Below 1 ppm detection limit of ASTM D5185

 

Shipping
Shipping & Delivery
Vendor Info

Vendor Information

  • Store Name: Comnaz
  • Vendor: Comnaz
  • No ratings found yet!
5
1 review
1
0
0
0
0

1 review for Shell Diala S4 ZX-I

Clear filters
  1. Mateo

    Shell Diala S4 ZX-I is presented as a premium transformer oil for severe conditions. My concern is regarding its long-term performance and maintenance in large power transformers. What are the key indicators or tests I should be regularly monitoring to ensure the oil is maintaining its dielectric strength and oxidation stability over its extended service life, and to preemptively identify any potential degradation or contamination issues?

    • Lubesta

      Maintaining the integrity of transformer oil like Shell Diala S4 ZX-I is critical for the reliable operation of power transformers. Regular monitoring and testing are essential to ensure its long-term performance. Key indicators and tests you should routinely perform include:

      Dielectric Breakdown Voltage (BDV): This is the primary indicator of the oil’s insulating capability and should be tested regularly to ensure it remains above acceptable limits. A declining BDV signals contamination or degradation.

      Water Content: Moisture is a major enemy of transformer oil, significantly reducing dielectric strength and accelerating oxidation. Regular water content testing (Karl Fischer titration) is crucial to keep levels low.

      Acid Number: An increasing acid number indicates oil oxidation and the formation of acidic byproducts. Monitoring this trend helps assess the oil’s remaining useful life and the need for potential mitigation actions like oil reclamation or replacement.

      Interfacial Tension (IFT): IFT measures the surface tension between oil and water, reflecting the presence of polar contaminants and oxidation products. A decreasing IFT indicates oil degradation.

      Dissolved Gas Analysis (DGA): DGA is a powerful diagnostic tool that analyzes the concentrations of dissolved gases in the oil. Different gases are generated by specific fault types (e.g., overheating, partial discharge). DGA trends can provide early warnings of developing transformer problems, allowing for proactive maintenance.

      Furanic Compounds: Furanic compounds are degradation products of cellulose insulation paper. Measuring furan levels provides insights into the condition of the paper insulation, which is critical for transformer longevity.

      Regularly trending these parameters, typically annually or bi-annually depending on transformer criticality and operating conditions, will provide a comprehensive picture of the oil’s health and help you proactively manage its condition, ensuring the long and reliable service life of your transformers. Consulting with a specialized transformer oil testing laboratory for interpretation and guidance is also highly recommended.

Add a review

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.