CITGO Transformer Oil N-II

CITGO Transformer Oil N-II is a top-tier insulating oil designed for critical electrical equipment. Its exceptional dielectric properties ensure safe operation, while its low viscosity allows efficient heat dissipation. Trust CITGO Transformer Oil N-II to keep your systems running smoothly.

Report Abuse
Description

Description

Product Description

CITGO Transformer Oil N-II is a highly refined naphthenic insulating oil with excellent dielectric and insulating properties. Developed specifically for use in oil-immersed transformers, circuit breakers, switches, and other oil-immersed electrical equipment, this fluid meets the stringent requirements of ASTM D3487 Type II.

 

Performance of CITGO Transformer Oil N-II

When it comes to ensuring the reliable operation of critical electrical systems, CITGO Transformer Oil N-II delivers exceptional performance:

Features of CITGO Transformer Oil N-II

  1. Dielectric Strength: CITGO Transformer Oil N-II boasts superior dielectric strength, preventing electrical breakdown and ensuring safe operation.
  2. Thermal Stability: Even under extreme temperatures, this oil maintains its stability, safeguarding your equipment.
  3. Inhibited Formula: Fully inhibited to protect against oxidation, corrosion, and sludge formation.
  4. Low Viscosity: Its low viscosity allows efficient heat dissipation within transformers.

Benefits of CITGO Transformer Oil N-II

  1. Extended Equipment Life: By minimizing wear and maintaining insulation integrity, CITGO Transformer Oil N-II prolongs the life of your electrical components.
  2. Reduced Maintenance Costs: Its high-quality formulation reduces the need for frequent oil changes and maintenance.
  3. Enhanced Safety: With excellent dielectric properties, this oil ensures safe operation even in demanding conditions.
  4. Environmental Compliance: CITGO Transformer Oil N-II is non-toxic and environmentally friendly.

 

Specifications

  • Viscosity at 40°C: 64 mm²/s
  • Viscosity at 100°C: 8.2 mm²/s
  • Viscosity Index: 95
  • Flash Point (COC): 225°C
  • Pour Point: -27°C
  • Mass Density at 15°C: 0.885 kg/l

 

Certifications

CITGO Transformer Oil N-II meets the following industry standards:

  • ASTM D3487 Type II

 

Health and Safety

  • Non-corrosive to machinery materials, gaskets, and seals
  • Rapid separation from water (ideal for oil-immersed systems)
  • Non-toxic (suitable for oil-mist lubrication systems)

 

Color

CITGO Transformer Oil N-II has a pale yellow color, reflecting its high-quality base oil.

 

API

CITGO Transformer Oil N-II adheres to industry standards, ensuring compatibility with various equipment.

 

Operating Temperatures

Suitable for use at temperatures within the specified range, CITGO Transformer Oil N-II performs consistently even in challenging conditions.

 

Container Size

Available in 55-gallon new drums, CITGO Transformer Oil N-II provides convenience and ease of handling.

 

Base Oil

CITGO Transformer Oil N-II is formulated from highly refined naphthenic base stocks, providing excellent lubrication properties.

 

Recommendations

For optimal results, follow the manufacturer’s recommendations for application and maintenance.

 

Applications

CITGO Transformer Oil N-II is recommended for:

  • Oil-immersed transformers
  • Circuit breakers
  • Switches
  • Other oil-immersed electrical equipment

 

In Which Industries Is CITGO Transformer Oil N-II Popular?

CITGO Transformer Oil N-II is widely used in the following industries:

  • Power generation and distribution
  • Electrical utilities
  • Industrial manufacturing
  • Renewable energy (wind and solar)

 

Price of CITGO Transformer Oil N-II

For pricing information and to place an order, contact us today! Our team will provide you with the best price for this high-quality transformer oil. Don’t miss out on this opportunity to enhance your equipment’s performance.

 

Flash Point of CITGO Transformer Oil N-II

The flash point of CITGO Transformer Oil N-II is 225°C. This high flash point ensures safety during handling, storage, and operation.

 

Viscosity of CITGO Transformer Oil N-II

  • Viscosity at 40°C: 64 mm²/s
  • Viscosity at 100°C: 8.2 mm²/s
  • Viscosity Index: 95

 

Frequently Asked Questions (FAQs) about CITGO Transformer Oil N-II

  1. Q: Can I use CITGO Transformer Oil N-II in outdoor transformers?
    • A: Yes, CITGO Transformer Oil N-II is suitable for both indoor and outdoor transformers. Its excellent thermal stability makes it a reliable choice.
  2. Q: Is CITGO Transformer Oil N-II compatible with other insulating oils?
    • A: Yes, it can be mixed with other insulating oils, but always follow manufacturer guidelines for proper blending.
  3. Q: How often should I test the dielectric strength of the oil in my transformer?
    • A: Regular testing is recommended, especially after any maintenance or repairs. Consult with experts to establish a testing schedule.

 

Datasheet Table: Specifications of CITGO Transformer Oil N-II

Property Value
Viscosity at 40°C 64 mm²/s
Viscosity at 100°C 8.2 mm²/s
Viscosity Index 95
Flash Point (COC) 225°C
Pour Point -27°C
Mass Density at 15°C 0.885 kg/l
Shipping
Shipping & Delivery
Vendor Info

Vendor Information

  • Store Name: Comnaz
  • Vendor: Comnaz
  • No ratings found yet!
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “CITGO Transformer Oil N-II”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.