NYNAS NYTRO 4000X
Rated 5.00 out of 5 based on 1 customer rating
(1 customer review)
Nynas NYTRO 4000X ensures the longevity and reliability of transformer oils. Its uninhibited formulation, exceptional performance, and competitive pricing make it an essential choice for maintaining electrical systems.
Specifications
- Antioxidant Concentration: Not applicable (uninhibited)
- Color: Pale yellow
- Container Sizes: Various options available
- Flash Point: Approximately 150°C (302°F)
- Viscosity: Low viscosity for efficient heat transfer
Categories: Lubricants, Nynas Nytro
Report Abuse
Description
Description
Product Description
Nynas NYTRO 4000X is a super-grade uninhibited transformer oil meticulously formulated to elevate the performance and longevity of electrical equipment. Whether you’re dealing with power transformers, distribution transformers, rectifiers, circuit breakers, or switchgears, NYTRO 4000X ensures optimal electrical insulation, efficient heat transfer, and reduced maintenance requirements. Let’s delve into the details of this exceptional product.
Performance of NYTRO 4000X
- Durable and Reliable: NYTRO 4000X is an inhibited super grade that conforms to IEC 60296 Edition 5.0. Developed to deliver maximum resistance to oil degradation, it provides outstanding oxidation stability for a longer transformer life with less maintenance.
- Specific Use: NYTRO 4000X has been specially developed for use in oil-filled electrical equipment, including power and distribution transformers, rectifiers, circuit breakers, and switchgears.
- Quality Material: Composed of high-quality mineral transformer oil, NYTRO 4000X exhibits excellent dielectric properties and oxidation stability.
- Affordable and On Sale: Nynas offers competitive pricing for NYTRO 4000X, making it an economical choice for utilities and maintenance teams.
Features of NYTRO 4000X
- Uninhibited Formula: NYTRO 4000X lacks added inhibitors, allowing it to react naturally with copper surfaces in transformers. This minimizes the risk of conducting compound formation.
- Efficient Heat Dissipation: Thanks to its low viscosity and viscosity index, this super grade offers extremely good heat transfer characteristics, ensuring heat is efficiently removed from the core and windings.
- Outstanding Oxidation Stability: Developed and formulated to deliver maximum resistance to oil degradation, NYTRO 4000X provides outstanding oxidation stability for enhanced transformer life and minimum maintenance.
- Very Good Low-Temperature Properties: Naphthenic characteristics allow the transformer to start at the lowest possible temperature – without using pour point depressants.
- High Dielectric Strength: This insulating oil both meets and exceeds the toughest demands on dielectric strength when stored and handled correctly.
Benefits of NYTRO 4000X
- Extended Equipment Lifespan: By avoiding inhibitor-related reactions, NYTRO 4000X significantly contributes to longer transformer life.
- Optimized Efficiency: Efficient heat dissipation enhances overall system performance, minimizing energy losses.
- Reduced Maintenance: Uninhibited oils require less frequent monitoring and maintenance, translating to cost savings.
- Environmentally Responsible: As a 100% recyclable oil, NYTRO 4000X aligns with sustainable practices.
Specifications
- Certifications: Complies with industry standards for uninhibited transformer oils.
- Operating Temperatures: Suitable for a wide range of temperature conditions.
- Container per Liter: Available in various container sizes for convenient handling and storage.
- Base Oil: High-quality mineral transformer oil.
Recommendations and Maintenance Conditions
- Storage: Store NYTRO 4000X in a cool, dry place away from direct sunlight.
- Handling: Follow standard safety procedures during handling and transfer.
- Applications: Ideal for power utilities, substations, and industrial facilities.
Industries Where NYTRO 4000X Is Popular
Nynas NYTRO 4000X, a super-grade uninhibited transformer oil, finds extensive use in various industries:
- Power Utilities: NYTRO 4000X plays a critical role in maintaining the reliability and efficiency of power distribution networks, substations, and electrical grids.
- Manufacturing and Industrial Facilities: Industries such as steel mills, chemical plants, and refineries benefit from NYTRO 4000X’s ability to protect transformer oils.
- Renewable Energy: Wind farms, solar power installations, and hydroelectric plants rely on NYTRO 4000X to enhance the lifespan of their transformers.
Price of NYTRO 4000X
For pricing information and special offers, contact us today! Our team will provide you with the best price for this high-quality uninhibited transformer oil.
Flash Point of NYTRO 4000X
NYTRO 4000X has a flash point of approximately 150°C (302°F), ensuring safe handling during maintenance.
Viscosity of NYTRO 4000X
NYTRO 4000X is a liquid solution with low viscosity, allowing easy mixing and distribution within transformer oils.
Frequently Asked Questions (FAQs)
- Q: Can NYTRO 4000X be added directly to transformer oil without dilution?
- A: Yes, NYTRO 4000X is a ready-to-use solution and can be added directly to uninhibited transformer oils.
- Q: How often should I check the inhibitor level in my transformer oil?
- A: Regular monitoring is recommended. Consult the manufacturer’s guidelines for specific intervals.
- Q: Is NYTRO 4000X compatible with other additives commonly used in transformer oils?
- A: NYTRO 4000X is designed to be compatible with most transformer oils. However, always verify compatibility before mixing.
Full Datasheet Information
| Specification | Value |
|---|---|
| Antioxidant Concentration | Not applicable (uninhibited) |
| Color | Pale yellow |
| Container Sizes | Various options available |
| Base Oil Compatibility | High-quality mineral transformer oil |
Shipping
Shipping & Delivery
Vendor Info
Vendor Information
- Store Name: Comnaz
- Vendor: Comnaz
- No ratings found yet!
More Products
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for NYNAS NYTRO 4000X
Clear filters
Add a review Cancel reply

Liam –
The NYNAS NYTRO 4000X is described as a transformer oil with excellent electrical properties. I’m concerned about its gassing tendency, especially in high-voltage applications. What is the gassing tendency of NYTRO 4000X, as measured by ASTM D3487 or IEC 60628 methods (specifically, Method A and Method B), and what are the typical values? Is this oil suitable for use in transformers with increased operating temperatures exceeding standard thresholds?
Lubesta –
Gassing tendency is a critical parameter for transformer oils, directly impacting their long-term performance and insulation integrity. ASTM D3487 and IEC 60628 are standard methods for measuring gassing tendency. Method A (modified Pirelli method) measures the oil’s ability to absorb gas, while Method B measures its tendency to release gas. A negative gassing tendency (absorbing gas) is generally desirable. A high-quality transformer oil like NYNAS NYTRO 4000X should have a gassing tendency within the acceptable range specified by these standards. While the product page only mentions “excellent electrical properties,” you must consult the technical data sheet from NYNAS or Lubesta to find the exact gassing tendency values. Regarding higher operating temperatures, the oil’s thermal stability and oxidation resistance become even more critical. Again, consult the data sheet for specific temperature limits and the oil’s performance under accelerated aging tests. Factors to consider will be the oil’s flash point, fire point, and viscosity at operating temperatures.